《少妇连续高潮抽搐痉挛昏厥》_久久久亚洲福利精品午夜_熟妇人妻久久中文字幕_中文字幕无线观看_久久久精品中文字幕综合

產(chǎn)品列表PRODUCTS LIST

聯(lián)系信息

  • 電話:
    189-2580-2250
  • 傳真:
    18925802250
  • 服務(wù)熱線:
    0769-82205353
首頁(yè) > 技術(shù)與支持 > FLTM BO 116-01_2007
FLTM BO 116-01_2007
點(diǎn)擊次數(shù):1217 更新時(shí)間:2019-08-27

FLTM BO 116-01_2007

本頁(yè)面標(biāo)準(zhǔn)信息均來(lái)源于網(wǎng)絡(luò)收集,或由參與標(biāo)準(zhǔn)制定的供應(yīng)商提供,只作為參考使用,為確保測(cè)試結(jié)果的準(zhǔn)確性、節(jié)省您的時(shí)間,如需FLTM BO 116-01_2007標(biāo)準(zhǔn)詳細(xì)信息或FLTM BO 116-01_2007具體測(cè)試方法,請(qǐng)與我們技術(shù)人員聯(lián)系或給我們留言,我們將為您提供相關(guān)的技術(shù)支持。

 

FLTM-BO-116-01標(biāo)準(zhǔn)簡(jiǎn)介

FLTM-BO-116-01 汽車內(nèi)飾材料暴曬試驗(yàn)標(biāo)準(zhǔn):水冷式氙弧燈氣候試驗(yàn)箱方法

FLTM  BO 116-01_2007標(biāo)準(zhǔn)英文版

EXPOSRE OF INTERIOR TRIM MATERIALS IN A CONTROLLED IRRADIANCE

WATER COOLED XENON-ARC APPARATS

Application

This procedure is used to determine the effects of simulated weather on interior trim materials using a controlled irradiance water cooled xenon-arc Weather-Ometer® with an auxiliary lantern and filters.

Apparatus Required

Operating Filter

335 nm long pass filters (SF-5 filters) or equivalent provided the transmission spectrum is within 95% of the SF-5 filter transmission at all wavelengths. The filters are reversible unless otherwise marked by a coating or etching.

Dimensions for the Ci 5000 series Weather-Ometer®:

339 mm +/- 0.13 mm x 70 mm +/- 0.13 mm x 3 mm +/- 0.52 mm

Dimensions for the Ci 3, Ci 6 & Ci 4000 Weather-Ometer®:

220 mm +/- 0.13 mm x 70 mm +/- 0.13 mm x 3 mm +/- 0.52 mm

Lamp Sensor Irradiance Filter

420 nm Irradiance Filter

Available from:

Atlas Material Testing Technology LLC

4114 Ravenswood Ave.

Chicago, IL 60613 SA

Calibration Lamp

The calibration lamp must be calibrated to 420 nm with the lantern assembly removed.

Available from:

Atlas Material Testing Technology LLC

4114 Ravenswood Ave.

Chicago, IL 60613 SA

Sample & Test Conditions

Sample Conditioning

All test values indicated herein are based on material conditioned in a controlled atmosphere of 21 +/-2 °C and 50 +/- 5% relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified.

Test Conditions

Testing conditions such as black panel temperature, dry bulb temperature, humidity, light cycle times and dark cycle times are equivalent to those outlined in SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Table 1,Section 6.1.5.

Place the 335 nm long pass filters (SF-5 filters) or equivalent into the auxiliary lantern. Orient thelantern around the xenon-arc lamp assembly which is equipped with the Quartz/Type "S" Borosilicate filtered xenon-arc lamp source as outlined in SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Apparatus Set-p, Section 6.

Exposures are monitored based on measured light at 1.06 W/m2 -/nm@420 nm SAE J2412 –Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance XenonArc Apparatus, Table 1.

Calibration

Equipment Calibration

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Appendix A, Section A.3 and Appendix B.

Maintenance

Equipment Maintenance

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Appendix A.

Note: SF-5 auxiliary filters should be cleaned at every lamp calibration period or more frequent if necessary.

SF-5 filters and the 420 nm interference filter should be changed per the manufacturer's recommendations/or within 13,000 hours of use.

Exposure

Sample Exposure

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Test Procedure, Section 7.

Evaluation & Reporting

Sample Evaluation and Exposure Report

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Evaluating and Reporting, Section 8 and Exposure Report, Section 9.

AATCC Gray Scale, 10 Step, According to AATCC Evaluation Procedure 1/ISO 105-A02 for Evaluation of Color Change.

FLTM BO II--01_2007測(cè)試機(jī)構(gòu)

 

pon request measure the gloss with a 60° glossmeter (or as specified in the applicable Engineering Standard) according to FLTM BI 110-01. Record the unexposed and exposed gloss.

Chemicals, materials, parts and equipment referenced in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities.

上一篇:GB 16776-2005

下一篇:ETAG 002-1999

返回列表>>

粵公網(wǎng)安備44190002001386號(hào)